If your pressure washer pulses, surges or sputters, check the water supply before touching the pump. A pump that is starved of water or sucking air will pulse, and the test takes two minutes.

The bucket test
- Disconnect the hose from the machine.
- Open the faucet fully and time how long it takes to fill a 5-gallon bucket.
- Flow in GPM = 5 ÷ (seconds ÷ 60).
Example: a 5-gallon fill in 120 seconds is 2.5 GPM. In 60 seconds it is 5 GPM. Compare the result with the GPM printed on your machine. The nozzle tip listing for the nozzle tip set is rated 2.5 GPM, so a faucet that fills the bucket slower than 2 minutes cannot keep up with a 2.5 GPM pump. Your own machine's rating is the one that counts.
If the flow is fine, check these
| Cause | What to do |
|---|---|
| Kinked or too-thin garden hose | Straighten it; use a 3/4 inch hose that is not coiled tight. |
| Clogged inlet screen | Remove and rinse it, or add an inline sediment filter. The listing gives a 80 psi maximum. |
| Air in the system | Connect the water, squeeze the trigger until a steady stream runs, and only then start the motor. |
| Leaking or missing washer at the inlet | Replace the rubber washer so the pump does not pull in air. |
| Partly clogged or worn tip | Clear or swap it. |
Caution
Do not run a pump dry. If the bucket test shows very low flow, fix the supply first or you risk damaging the pump seals.
See also losing pressure: 6 steps, connecting the hose to the inlet, and cleaning an inline filter.